Correspondence to: Prof. Adrian Barbilian, MD, PhD, Chief of the Orthopaedics and Traumatology Department Orthopaedics and Traumatology Department, “Carol Davila” University Emergency Military Hospital, Bucharest, 88 Mircea Vulcanescu Street, Code 010825, Bucharest, Romania, Phone: +021 319 3046, E-mail: adrianbarbilian@yahoo.com

Abstract

The article represents a retrospective clinical and radiological study.

Objective. To assess the safety and the stability in time of the Unit Rod instrumentation in the treatment of severe neuromuscular scoliosis in children and adolescents.

Summary. The treatment of patients with neuromuscular scoliosis always represents a challenge. The patients are debilitated and usual interventions are very long with great loss of blood. Serious complications can compromise the result of the surgery. The technique we used (the Unit Rod) is worldwide recognized, is simple, and gives excellent stability with a low rate of complications.

Methods. We conducted a clinical and radiological retrospective study with a follow-up of at least 4 years in 58 patients with serious neuromuscular conditions, most of them being non-walkers. They were surgically treated by using mostly the Unit Rod technique, in the department of Paediatric Orthopaedics of the Rouen University Hospital, France, between 2000 and 2008. The back fusion was generally from T2 to pelvis. We used the Galveston technique for the patients who needed a pelvic fixation.

Results. The mean Cobb angle correction was of 67% immediately after surgery; the correction of the curve decreased in time only in 4% of the cases. Pelvic obliquity was also very well corrected: 73% immediately and 70% at the last radiological follow-up. The mean operative time was of 175 minutes compared to 269 minutes for screws and hooks instrumentation. The most common complication for our technique was the radiolucent halo that appeared around the pelvic inserts. There was no significant degradation in time of the correction obtained.

Conclusions. The use of this technique is safe, gives excellent results, achieving significant improvements in the postoperative functional status of the patients. The intra- and postoperative complications were minor. The advantage of using this method is the low cost of the material and technical simplicity, the corrective results being the same as the ones obtained with other techniques.

Keywords

About this article

PMC ID: 5141401
PubMed ID: 27928445
DOI: 

Article Publishing Date (print): Oct-Dec 2016
Available Online: 

Journal information

ISSN Printing: 1844-122X
ISSN Online: 1844-3117
Journal Title: Journal of Medicine and Life

Copyright License: Open Access

This article is distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use and redistribution provided that the original author and source are credited.


SCImago Journal & Country Rank

Issues

Special Issues